Information for Bar Road, Coventry
Status: ExistingPlanning Region: West Midlands
Planning Sub-Region: West Midlands Met Districts
Operator: The Coventry & Solihull Waste Disposal Company Ltd
Capacity: 315,000
Campaign Group(s): Coalition for Recycling and Against Coventry Incinerator (CRACIN)
Notes: Nearish the end of its operational life. It is expected that the facility will be refurbished rather than decommissioned because the plant is connected to a district heating scheme [Source]. The Council(s) purchased Tom White Waste's assets in January 2025 which included the incinerator and agreed a 25-year agreement to lease them back to Tom White Waste [Source]. In January 2025 it was reported that: "Coventry and Solihull Waste Disposal Company (CSWDC) has revealed its Coventry-based facility is unable to meet key emission limits under the recently updated Waste Incineration BREF (WI BREF). The issues for the facility, which is ultimately owned by CSWDC’s shareholders Coventry City Council, Solihull Metropolitan Borough Council and Warwickshire County Council, were revealed in an environmental permit application" [Source]. (Entry updated 2025-07-31)
Waste management for England 2024: Operational (Environment Agency)
Uses data from 2024 Waste Data Interrogator - Version 2 released by the Environment Agency under the Environment Agency Conditional Licence. © Environment Agency copyright
Permit: NP3739PD
| Date First Permitted | Operator Name | Site Name | Site Address | Type | Permitted Capacity (tonnage) | Tonnage Incinerated in 2006 | Tonnage Incinerated in 2007 | Tonnage Incinerated in 2008 | Tonnage Incinerated in 2009 | Tonnage Incinerated in 2010 | Tonnage Incinerated in 2011 | Tonnage Incinerated in 2012 | Tonnage Incinerated in 2013 | Tonnage Incinerated in 2014 | Tonnage Incinerated in 2015 | Tonnage Incinerated in 2016 | Tonnage Incinerated in 2017 | Tonnage Incinerated in 2018 | Tonnage Incinerated in 2019 | Tonnage Incinerated in 2020 | Tonnage Incinerated in 2021 | Tonnage Incinerated in 2022 | Tonnage Incinerated in 2023 | Tonnage Incinerated in 2024 | Tonnage Incinerated in 2022 | Tonnage Incinerated in 2023 | Tonnage Incinerated in 2024 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 20/12/2005 | The Coventry & Solihull Waste Disposal Company Limited | Coventry Incinerator | CSWDC Limited,Bar Road,COVENTRY,West Midlands CV3 4AN | Municipal and/or Industrial & Commercial | 315,000 | 210,200 | 232,800 | 241,733 | 245,187 | 240,246 | 230,563 | 229,995 | 244,633 | 264,830 | 273,728 | 282,849 | 292,989 | 288,537 | 298,854 | 313,268 | 295,135 | 297,821 | 291,805 | 291,464 | 297,821 | 291,805 | 291,464 |
Waste management for England 2023 & 2024: Waste received
2023: Uses data from 2023 Waste Data Interrogator - Version 2 released by the Environment Agency under the Environment Agency Conditional Licence. © Environment Agency copyright
2024: Uses data from 2024 Waste Data Interrogator - Version 2 released by the Environment Agency under the Environment Agency Conditional Licence. © Environment Agency copyright
Permit: NP3739PD
Form: Solid
Recorded Origin: West Midlands
Origin WPA: West Midlands (WPA Not codeable)
Origin Region: West Midlands
Fate: Incineration
R and D code: D10
| EWC Waste Desc | Waste Code | SOC Category | SOC Sub Category | Tonnes Received (2023) | Tonnes Received (2024) |
|---|---|---|---|---|---|
| mixed municipal waste | 20 03 01 | 10 - Mixed ordinary wastes | Household and similar wastes | 288,395 | 290,855 (+0.9%) |
| absorbents, filter materials (including oil filters not otherwise specified), wiping cloths, protective clothing contaminated by dangerous substances | 15 02 02* | 07 - Non-metallic wastes | Textile wastes | 495 | 299 (-40%) |
| bulky waste | 20 03 07 | 10 - Mixed ordinary wastes | Household and similar wastes | 9 | |
| paper and cardboard | 20 01 01 | 07 - Non-metallic wastes | Paper and cardboard wastes | 2 | |
| other wastes (including mixtures of materials) from mechanical treatment of wastes other than those mentioned in 19 12 11 | 19 12 12 | 10 - Mixed ordinary wastes | Sorting residues | 2,914 |
Waste management for England 2023 & 2024: Waste removed
2023: Uses data from 2023 Waste Data Interrogator - Version 1 released by the Environment Agency under the Environment Agency Conditional Licence. © Environment Agency copyright
2024: Uses data from 2024 Waste Data Interrogator - Version 2 released by the Environment Agency under the Environment Agency Conditional Licence. © Environment Agency copyright
Permit: NP3739PD
EWC Sub Chapter: Incineration or pyrolysis of waste
| EWC Waste Desc | Waste Code | Recorded Destination | Destination WPA | Destination Region | Fate | R and D code | SOC Category | SOC Sub Category | Tonnes Removed (2023) | Tonnes Removed (2024) |
|---|---|---|---|---|---|---|---|---|---|---|
| bottom ash and slag other than those mentioned in 19 01 11 | 19 01 12 | Derbyshire | Derbyshire | East Midlands | Recovery | R05 | 12 - Mineral wastes | Combustion wastes | 44,622.68 | 44,211.93 (-0.9%) |
| solid wastes from gas treatment | 19 01 07* | Peterborough | Peterborough | East of England | Landfill | D05 | 12 - Mineral wastes | Combustion wastes | 12,310.91 | 12,268.64 (-0.3%) |
| ferrous materials removed from bottom ash | 19 01 02 | Derbyshire | Derbyshire | East Midlands | Recovery | R04 | 06 - Metallic wastes | Ferrous metal waste and scrap | 5,695.63 | 4,987.43 (-12%) |
Environment Agency 2024 Pollution Inventory: Substances
Uses data from the Pollution Inventory 2024 released by the Environment Agency under the Open Government License.
Permit: NP3739PD
SITE ADDRESS: Coventry Incinerator Bar Road
ROUTE NAME: Air
METHODNAME: Calculated
METHODTEXT: Extractive sampling
METHODDESCRIPTION: Calculation method prescribed by us in an operating permit or licence for the facility
| SUBSTANCE NAME | QUANTITY RELEASED (kg) |
|---|---|
| Carbon dioxide | 273,887,000 |
| Carbon Dioxide From Qualifying Renewable Fuel Sources | 164,332,000 |
| Nitrogen oxides (NO and NO2) as NO2 | 278,000 |
| Ammonia | 15,500 |
| Particulate matter - PM10 | 1,120 |
| Particulate matter - PM2.5 | 1,120 |
| Cadmium | 2.30 |
Environment Agency 2025 Pollution Inventory: Substances
Uses data from the Pollution Inventory 2025 snapshot from April 2025 released by the Environment Agency under the Open Government License. The data may change in the final version.
Permit: NP3739PD
SITE ADDRESS: The CSWDC Waste to Energy Plant Bar Road Coventry
ROUTE NAME: Air
METHODNAME: Calculated
METHODDESCRIPTION: Calculation method prescribed by us in an operating permit or licence for the facility
| SUBSTANCE NAME | QUANTITY RELEASED (kg) | METHODTEXT |
|---|---|---|
| Carbon dioxide | 283,342 | |
| Ammonia | 9,100 | |
| Particulate matter - PM2.5 | 1,134 | |
| Particulate matter - PM10 | 1,134 | |
| Cadmium | 3.5 | |
| Mercury | 1.69 |
GHG Performance in 2023
Uses data from Pollution Inventory 2023 extract and Annual Peformance Reports submitted by operators and released by the Environment Agency under the Open Government License
Permit: NP3739PD
| Permitted capacity (ktpa) | Total waste combusted | CO2 (kg) | CO2 per tonne (kg) | CO2 Source |
|---|---|---|---|---|
| 315 | 291,805 | 288,669,000 | 989 | Pollution Inventory |
APR Summary 2024 & 2025
Details taken or derived from the Annual Performance Report submitted by the operator
Permit: NP3739PD
| Entry | Value (2024) | Value (2025) | Notes (2024) | Notes (2025) |
|---|---|---|---|---|
| Plant Size TPA | 315,000 | 315,000 | The Coventry and Solihull Waste Disposal Company Limited | |
| Plant Size MWth | 77 | 77 | ||
| Plant Size MWe | 1,800.00% | 17.70 | ||
| Power Generated Year Total | 38,055.46 | 97,341.37 (+156%) | ||
| Power Generated kWh per tonne | 13,057.00% | 335.28 | ||
| Power Exported Year Total | 1,817,700.00% | 55,716.00 | ||
| Power Exported kWh per tonne | 62.36 | 191.90 (+208%) | ||
| Power Imported Year Total | 100.00 | 1,822.00 (+1,722%) | ||
| Power Imported kWh per tonne | 0.34 | 6.28 (+1,747%) | ||
| Parasitic Load Year Total | 0.52 | 0.44 (-15%) | ||
| Thermal Energy Exported Year Total | 15,594.00 | 12,324.00 (-21%) | ||
| Total Waste Received Year Total | 291,464.11 | 290,332.48 (-0.4%) | ||
| Total Waste Combusted Year Total | 291,464.00 | 290,332.48 (-0.4%) | Household / Local Authority (99.90%) | Household / Local Authority (100.00%) |
| Permit Breaches Year Total | 0.00 | 0.00 | ||
| Annual CO2 Mass | 273,887.00 | 270,629.30 (-1%) | CEMs data used to record CO2 and flow with running hours to produce a mass value for the year. Please note that G1 the main turbine was off for the whole of 2024 awaiting parts and refurb following a major failure in May-23. Annual mass of carbon dioxide is then higher in 2024 at 15.07 however it was only 5.33 in 2023 . This is due to only have G2 available. To note we are still supplying majority of in house electricity to ourselves BRING energy and Sherbourne next door and supplying district heating to Coventry City Centre. When G1 returns to service this figure will normalise. | CEMs data used to record CO2 and flow with running hours to produce a mass value for the year |
| Annual CO2 Mass Per Tonne | 0.94 | 0.93 (-1%) | ||
| Annual CO2 Mass Per Mwh | 4.86 | |||
| Annual N2O Mass | 7.20 | 6.10 (-15%) | CEMs data used to record N2O and flow with running hours to produce a mass value for the year (For all years) | |
| Total CO2 N2O | 272,245.80 | |||
| Biogenic CO2 Percentage | 0.60 | 0.59 (-2%) | C14 sampling on common exit duct (For all years) | |
| Biogenic Percentage NCV | 0.55 | 0.54 (-2%) | Using the Fichtner calculation/formula (For all years) | |
| Biogenic Percentage Mass | 0.60 | 0.59 (-2%) | Waste sampling data (For all years) | |
Entry on WikiWaste:
https://wikiwaste.org.uk/index.php/Coventry_EfW_PlantAnnual Performance Report files:
211-AnnualPerformanceReport-2018.pdf211-AnnualPerformanceReport-2019.pdf
211-AnnualPerformanceReport-2020.xlsm
211-AnnualPerformanceReport-2021.xlsm
211-AnnualPerformanceReport-2022.xlsm
211-AnnualPerformanceReport-2023.xlsm
211-AnnualPerformanceReport-2024.xlsm
211-AnnualPerformanceReport-2025.xlsm
Permit Variation files:
211-PermitVariation-2022.pdf211-PermitVariation-Decision-2022.pdf
Environment Agency Compliance Assessment Reports
Click here to see the incinerator compliance documents for existing English incineratorsStandard notice:
UKWIN (and therefore the UKWIN map) focuses on Municipal Waste Incinerators, whereas our colleagues at Biofuelwatch focus on biomass projects. If you are interested in biomass incinerators (including waste wood plants) over 20MW then please see the Biofuelwatch map of UK Biomass Power Stations. Those concerned about biomass plants, including waste wood plants, should email Biofuelwatch at biofuelwatch[at]gmail.com.Please be aware: There is always room for improvement, so please send updates to coordinator@ukwin.org.uk. Existing Incinerator means a facility that is operational or under construction/commissioning. A Potential Incinerator is a facility where there is a proposal for an incinerator (e.g. planning application or planning consent) or other reason to believe an incinerator might be built/proposed in the future. A Prevented Incinerator is something which used to be a proposal or expected incinerator which we do not believe is currently being progressed (e.g. because the project was cancelled, planning permission refused, or years have gone by since the permission was granted without any progress) - in some cases a facility marked as prevented is being progressed without us being aware or is subsequently revived. Capacity is usually the permitted or maximum advertised capacity of the facility.